Bioscience Biotechnology Research Communications

An International  Peer Reviewed Refereed Open Access Journal

P-ISSN: 0974-6455 E-ISSN: 2321-4007

Bioscience Biotechnology Research Communications

An Open Access International Journal

N.Z. Amalina1 and M.Y. Ina-Salwany1,2*

1Laboratory of Marine Biotechnology, Institute of Bioscience, Universiti Putra Malaysia, 43400 Serdang, Selangor, Malaysia.

2*Department of Aquaculture, Faculty of Agriculture, Universiti Putra Malaysia, 43400 Serdang, Selangor, Malaysia

Article Publishing History

Received: 18/08/2016

Accepted After Revision: 26/09/2016

ABSTRACT:

Vibriosis is one of a major problem in aquaculture sector causes by Vibrio species and gives bad impact on economy and social development. In addition, number of the infected people with vibriosis is increasing every year through consuming of contaminated fishes and other aquatic animals. To overcome this problem, researchers continuously develop new methods for identification and detection of Vibrio species. Those methods can be categorized based on the principle applied; conventional culture method, antigen-antibody based assay, nucleic acid amplification technology and lateral flow dipstick. The conventional culture method is a basis in identification of Vibrio but it is time consuming and requires skilled personnel. The nucleic acid amplification technology such as isothermal amplification assay in a combination of lateral flow dipstick is widely used since these assays offer rapid, easy to handle and high sensitivity and specificity detection methods. This paper also reviews and describes the available application and limitations of the studies involving Vibrio detection methods of aquaculture field. As a conclusion, the development of new technologies is very important to improve the detection of Vibrio species as well as increasing the number of food production to meet human demands.

KEYWORDS:

Isothermal Amplification, Lamp, Lateral Flow Dipstick, Nucleic Acid Amplification, Pcr, Vibrio

Download this article as:

Copy the following to cite this article:

Amalina N. Z, Ina-Salwany M. Y. Recent Advancements in Molecular Detection of Vibrio Species in Aquatic Animals: A Review. Biosc.Biotech.Res.Comm. 2016;9(3).


Copy the following to cite this URL:

Amalina N. Z, Ina-Salwany M. Y. Recent Advancements in Molecular Detection of Vibrio Species in Aquatic Animals: A Review. Biosc.Biotech.Res.Comm. 2016;9(3). Available from: https://bit.ly/2MsgsZc


Introduction

Nowadays, aquaculture becomes an important food production sector especially from fishes, molluscs, crustaceans and other aquatic animals. According to FAO (2013), 128 million tons of fishes, molluscs and crustaceans were provided for human food. The number of food production will be increasing every year due to high demand for food. In addition, aquaculture is a significant socio-economic activity through employment, income generation, domestic and international trade, and provide livelihoods especially for rural communities (Edward et al., 2002). Unfortunately, the diseases problem of aquaculture sector is increasing every years caused by bacteria, viruses, fungi, parasites and other emerging pathogens (Adams and Thompson, 2011). This problem also effects the economic and social development worldwide.

Vibriosis is one of a major problem in aquaculture sector and caused outbreaks of aquatic animal diseases. It leads to significant mortality in aquatic animals, loss of food and severe economic losses (Buller, 2014; Gauthier, 2015).

Besides, this bacterium can infect human through consumption of raw or undercooked fish and other aquatic animals. Outbreaks of vibriosis have been reported worldwide caused by Vibrio alginolyticus, V. parahaemolyticus, V. harveyi, V. anguillarum, V. vulnificus and other Vibrio species in various countries, including United State, Canada, China, Taiwan, India and Japan (Chiou et al., 2000; Alam et al., 2003; Deepanjali et al., 2005; Xie et al., 2005; CDC, 2013). Over 80 000 cases and 100 deaths caused by vibriosis were reported in United State every year (Scallan et al., 2011). According to CDC, the number of cases in U.S. was increasing 75% in 2013 compared to 2006 until 2008 with majority of cases caused by V. parahaemolyticus and V. vulnificus (FoodNet, 2014).

Vibrio is a gram negative bacterium from family Vibrionaceae, rod shape and undergoes facultative anaerobic respiration. Naturally Vibrio found in estuarine, marine environments, normal flora of organisms and also can be pathogenic (Wang et al., 2009; Haldar et al., 2011; Chatterjee and Haldar, 2012). Usually, there are no specific symptoms of infection of vibriosis observed in marine life. The symptoms are similar with other bacteria diseases starting with lethargy and loss of appetite. The skin becomes discolored, red and boil-like sores may appear on the skin surface. As a disease progress, erythema or bloody blotches can be found around the mouth and fins. The gut and rectum can be bloody and filled with fluid if an early treatment not be given (Wang et al., 2009). Thus, all these symptoms are not proof of a vibriosis and require a further isolation and identification of bacteria.

Therefore, culture method has been developed for the identification of bacteria species in aquatic animal and marine environment. The bacteria are allowed for multiplying in culture media under controlled laboratory conditions and further identified using gram staining and biochemical tests. However, this method is tedious, time consuming and requires skilled personnel to pick right colonies of a plate. In addition, culture method unable to differentiate species levels due to similar morphology such as V. cholerae, V. alginolyticus and V. fluvialis which appeared yellow color on agar plates (Oxoid, UK).

To overcome those limitations, the antigen-antibody based assay was developed to test presence of specific antibody or antigen in aquatic samples. A specific antibody is used for recognition of antigen from pathogenic bacteria. Even though this assay is rapid and easy to perform, but it is unable to differentiate Vibrio species because they have same antigens (Chen et al., 1992). The molecular approaches based on synthesis of nucleic acid were developed for producing more sensitive and specific assays such as polymerase chain reaction (PCR), real-time PCR, multiplex PCR, reverse-transcriptase PCR, touchdown PCR and so on. However, those assays required expensive thermocycler machine to amplify the nucleic acid based on three different temperatures.

Thus, a novel isothermal amplification assay was developed in early 1990s as an alternative to the PCR assay. The amplification of nucleic acid can be performed in a single temperature (isothermal condition) which mimics in vivo synthesis of DNA. The isothermal amplification assay can be performed without the need for a thermocycling apparatus. In addition, the isothermal amplification assays also more sensitive and specific, rapid and easy to perform. However, the detection and visualization of isothermal products still requires conventional agarose gel electrophoresis system. This agarose gel electrophoresis is laborious, requires special equipment, time consuming and must be operated by skilled personnel. Thus, an alternative method, a lateral flow dipstick is developed for the detection of isothermal products. Based on previous study, the lateral flow dipstick is rapid (within five to ten mins), easy to perform, does not require special equipment and can be visualized using naked eyes (Wain and Hosoglu, 2008; Mugasa et al., 2009).

Conventional Culture Methods

Culture method is a gold standard for isolation of bacteria by using enrichment and selective medium. Basically, tryptic soy broth (TSB) is used to enrich amount of Vibrio from samples. Vibrio can grow in different environments due to its ability to live in saltwater, freshwater and living organisms. Vibrio grows well at pH 7 to 9, from neutral to alkaline condition. It also able to grow in high concentration of sodium chloride (NaCl) due to it character halophilic. A sodium chloride (NaCl) is added with the TSB when samples were collected from saltwater. In laboratory, a halophilism test was performed with different concentration of NaCl (0 to 10%) and V. alginolyticus requires at least 3% NaCl and can tolerate until 10% NaCl for growth (Gomathi et al., 2013).

Thiosulfate citrate bile salts-sucrose (TCBS) agar is a common selective media used for isolation of Vibrio species (Jones et al., 2012). In order to perform a bacteria culture on the agar plate requires a lot of time to allow optimum growth of bacteria colonies. For example, bacteria are incubated at 30oC for 16-24 hours when isolated from environmental samples, while bacteria are incubated at 35oC for 24 hours when isolated from other samples (Oxoid, UK). Typical colonies of Vibrio can be varying in terms of size and color of colonies (showed in Table 1).

Table 1: Typical morphology of Vibrio colonies on TCBS agar
Organisms Size of colonies Color of colonies
Vibrio parahaemolyticus 3-5 mm diameter Blue colonies with green centers
Vibrio alginolyticus 3-5 mm diameter Yellow
Vibrio cholera 2-3 mm diameter Yellow and flat colonies
Vibrio vulnificus/ Vibrio mimicus 2-3 mm diameter Blue green
Vibrio harveyi 2-3 mm diameter Gray to bluish green colonies
Vibrio fluvialis 2-3 mm diameter Yellow

The biochemical profile of Vibrio species can be determined using API 20E diagnostic strip (bioMerieux, Durham, NC). The API 20E test strip has 20 miniature biochemical tests of different medium; Citrate (CIT), Voges-Proskauer (VP), Urease (URE), hydrogen sulfide (H2S), amino acid decarboxylations (ADH), gelatin hydrolysis (GEL) and others. Bacteria are mixed with two percents of NaCl as the suspension solution, added to the API strip and incubated at 37oC for 18-24 hours. After that, changes of the color reaction were read and converted to a seven digit code known as Analytical Profile Index (API). The codes are matched with the manufacturer’s database and give the bacteria identification as a genus and species. According to Jones (2012), API 20E test was able to identified 41.8% of V. parahaemolyticus from oysters isolates and 54.6% of V. parahaemolyticus from clinical isolates. The API codes were misidentified several bacteria isolate such as V. vulnificus, Aeromonas hydrophila, V. fluvialis, V.cholerae and V. mimicus (Jones et al., 2012).

However, these conventional methods have disadvantages such as less specific, tedious, require skilled personnel and cannot differentiate between Vibrio species, especially V. parahaemolyticus and V. alginolyticus which are biochemically similar (Mustapha et al., 2013).

Antigen-Antibody Based Assay

Vibrio species possesses three antigenic components; heat-labile K-antigen (capsular polysaccharide), heat-stable somatic O-antigen (lipopolysaccharide) and H-antigen (flagellar). Those antigenic components of Vibrio can be determined via agglutination tests where the bacteria culture are reacted with specific antiserum to formed clumps or agglutinate particles. To determine the O-antigens, the bacteria should be heated at boiling temperature for one to two hours. This step is important to removed K-antigen from Vibrio since K-antigen masked the O-antigen.

The Mono-aqua test kit (BIONOR, Tamar Laboratory Supplies Ltd., Israel) is a commercial agglutination tests for rapid preliminaries screening of pathogens such as V. anguillarum and V. salmonicida. The principle used is a mono-disperse particles coated with specific antibodies will be reacted with fish pathogenic bacteria (antigen) and form a visible granular particle agglutination pattern. This kit is rapid (can be performed in 30 minutes) and inexpensive. However, the samples have to be cultured overnight before testing and make this test tedious and time consuming (Romalde et al., 1995). Also, Vibrio species are serologically identical based on a study reported that most of the Vibrio species share H-antigen at 52-kDa protein including V. parahaemolyticus, V. alginolyticus, V. anguillarum and V. ordalii (Chen et al., 1992).

An aqua-rapid and aqua-EIA test kits were developed as a modification of previous kit based on Enzyme Immunoassay (EIA) principle. EIA is also known as enzyme-linked immunosorbent assay (ELISA), combination of the antibody binding with certain enzyme for the detection and quantification of antigen (pathogenic bacteria) (Lequin, 2005). By using the EIA principle, both kits can be used for direct identification of fish pathogens without needs of culture. Thus, these kits are rapid, easy to performed and suitable to be used at farm site. The aquaEIA test kit is using semiautomated system, while aqua-rapid using manual system.

The dot immunoassay method is one of the antigen-antibody based assay that has been used to detect V. alginolyticus and A. hydrophila isolated from shrimps and fishes. The bacteria culture is diluted before spotted onto the nitrocellulose paper and allow reacting with antiserum raised against V. alginolyticus and A. hydrophila. Even though this method is simple, but it is less specific due to cross-reaction of V. alginolyticus antiserum with V. parahaemolyticus, V. harveyi and V. anguillarum (Mishra, 1998).

Nucleic Acid-Based Assay

Molecular diagnostics involving nucleic acid amplification is the most common methods used for the detection and identification of infectious diseases. Polymerase chain reaction (PCR) is a main technique used for nucleic acid amplification. PCR provides a rapid, high sensitivity and specificity compared to the conventional culture methods for differentiation and identification of species. It is also able to identify housekeeping genes and different virulence genes among Vibrio species. In addition, the PCR assay is able to simultaneous detection of multiple pathogens in a single reaction known as multiplex PCR assay. The PCR assay is based on the amplification of nucleic acids using specific primer and DNA polymerase at three different temperatures; denaturation, annealing and extension that repeated in a number of cycles until certain amount of DNA obtained. Thus, the PCR assay requires a thermal cycler to complete the amplification process.

Researchers were performed extensive studies using PCR assay for the identification and differentiation of Vibrio infected fishes, molluscs, crustaceans and other aquatic animals. Various genes were used in designing primers for specific amplification of target gene of Vibrio. A 16S rRNA gene is highly conserved among bacteria species based on hyper variable region that contains similar species-specific sequence which is useful for bacteria identification. In 2006, Bramhachari and Duey developed a PCR for detection of V. harveyi using 16S rRNA. Kim and Jeong (2001) was developing a PCR targeting the same 16S rRNA gene to identify pathogenic V. vulnificus in marine environments. Similarly, Yong in 2006 targeted gene for identification of bacteria from aquaculture systems.

toxR gene is a virulence gene encodes for regulatory gene of toxin operon. A PCR for detection of V. harveyi targeting toxR gene was successfully developed with 100% specificity (Conejero and Hedreyda2003). In 2016, the toxR gene is found to be more specific compared to the gyrB gene in identification of V. parahaemolyticus in fish and coastal environment in Jordan (Alaboudi et al., 2016). GyrB gene is encodes for the B subunit protein of DNA gyrase (topoisomerase type II). Previous study was found the degree of homology of toxR gene between V. parahaemolyticus and V. cholerae was 52% (Kim et al., 1999).

Other virulent genes used for identification of Vibrio species were thermostable direct hemolysin (tdh), thermolabile hemolysin (tlh) and thermostable direct hemolysin-related hemolysin (trh) (Jones, 2012). Mohammed and Jerjees (2015) proved that the 12% and four percents of V. parahaemolyticus isolated from fresh shrimp have the tdh and trh genes, respectively. Other study revealed the tdh and trh genes were 98% homology between V. alginolyticus and V. parahaemolyticus isolated from shrimp (Gargouti et al., 2015). In 2016, Li and his friends found a unique gene for V. parahaemolyticus, blaCARB-17 gene which has the lowest degree of similarity (78% homology) with V. alginolyticus compared with other virulence genes such as tlh (85%), atpA (97%) and toxR (86%) genes. The PCR assay targeting for blaCARB-17 gene was produced 100% sensitivity and specificity (Li et al., 2016).

A multiplex PCR (mPCR) assay was used for simultaneous detection of more than one Vibrio species in a single test. Xie (2005) was developing the mPCR assay for detection of seven virulence genes targeted for V. parahaemolyticus and V. alginolyticus from shrimp, fish and seawater in Guangdong Coast, China (tlh, trh, tdh, toxR, toxRS, ctxA and VPI). This study found that the V. alginolyticus, V. parahaemolyticus and V. cholerae possess homology using toxR, tlh and VPI genes. In 2011, Izumiya was developed a highly sensitive and specific mPCR assay for the detection of V. cholerae, V. parahaemolyticus and V. vulnificus from seawater sample using dnaJ gene. Similarly, Xu in 2014 was targeted dnaJ gene for detection of five Vibrio species; V. parahaemolyticus, V. vulnificus, V. alginolyticus, V. cholerae and V. mimicus from seafood samples.

In addition, the 16S rRNA gene was included in the mPCR assay as a Vibrio species control to avoid any doubt regarding target of V. parahaemolyticus, V. mimicus, V. vulnificus and V. cholerae from shrimp and crab samples (Amin and Salem, 2012). The 16S rRNA gene also used as an internal amplification control (IAC) in the mPCR assay targeting V. alginolyticus, V. parahaemolyticus, V. vulnificus and V. cholerae (Wei et al., 2014). The internal amplification control is a mandatory for diagnostic using PCR assay. IAC is used for validation of negative result whether it is truly negative or due to malfunction of thermal cycler, incorrect PCR mixture or presence of inhibitory substances in the sample (Hoorfar et al., 2003).

Based on previous studies, the PCR assay is highly sensitive and specific, able to simultaneous detection of many pathogens in a single tube and successful detect Vibrio species. However, this assay requires expensive equipment, time consuming and requires trained personnel. Based on the WHO guidelines, a develop diagnostic device must be affordable, sensitive, specific, user friendly, rapid and robust, equipment free and deliverable to end used (ASSURED) (Mabey et al., 2004). Thus, an alternative platform known as isothermal amplification assay was developed in order to fulfill this guideline.

Isothermal Amplification Assay

Isothermal amplification techniques have been developed since early 1990s as an alternative to the polymerase chain reaction (PCR) assay. This technique is used to amplify DNA, RNA, cells and proteins. The isothermal amplification assay can be performed at one temperature rather than the PCR assay which required three different temperatures (Notomi et al.2000; Chow et al., 2008; Fang et al., 2010). Therefore, the isothermal amplification can be performed using simple heating devices (e.g., water bath or heating block) without the need of thermocycling apparatus. In addition, the isothermal product can be directly visualized by naked eyes on the form of turbidity or fluorescence, eliminating the need for electrophoresis system as used in the PCR assay. Thus, the isothermal amplification are rapid, user friendly, high sensitivity and specificity and can be performed without expensive equipment.

Nowadays, several types of isothermal amplification technique were developed for the detection of pathogenic bacteria such as loop-mediated amplification (LAMP), nucleic acid sequence-based amplification (NASBA), strand displacement amplification (SDA), helicase dependent amplification (HDA), rolling circle amplification (RCA) and transcription mediated amplification (TMA) assays (Compton, 1991; Walker et al., 1992; Fire and Xu, 1995; Notomi et al., 2000; Vincent et al., 2004). Each isothermal assay had their own mechanisms to promote a next cycle of DNA synthesis. Differ with the PCR assay that used heat denaturation of double stranded DNA to initiate next cycles of DNA synthesis; the isothermal assays use various accessory proteins to open the double stranded DNA (Gill and Ghaemi 2008).

Loop-mediated amplification (LAMP) assay is the most popular isothermal amplification technique used in aquaculture field. LAMP assay was developed by Notomi et al. (2000) for the identification of Hepatitis B virus. This assay was designed based on four to six primers to recognize six or eight distinct sequences on the template DNA. The nucleic acid is extended by the Bst polymerase to synthesis new DNA strands. The entire LAMP reaction can be performed in simple heating devices at 60 to 65oC for less than one hour. The amplified products will be mixture of stem-loop DNAs with various length and cauliflower-like structures with multiple loops (Notomi et al., 2000; Mori and Notomi, 2009). The products can be identified by using agarose gel electrophoresis (produced multiple bands of different sizes from ~300bp), restriction enzyme digestion (such as BamHIHindIII and others to produce two different bands) and Southern blot hybridization. Also, the LAMP products can be observed by naked eyes through usage of magnesium pyrophosphate, calcein, SYBR Green or other fluorescence dye (Prompamorn et al., 2011).

LAMP assay has been developed for the detection of Vibrio species such as V. alginolyticus, V. harveyi and V. parahaemolyticus from aquatic animals and environment (Cai et al., 2010, Di et al., 2015). The LAMP assay was developed for the detection of V. alginolyticus in mariculture fish using gyrB gene and it is ten-fold more sensitive than PCR assay (Cai et al., 2010). In addition, several studies revealed that the LAMP assay is superior to the PCR assay and conventional culture method for the detection of V. parahaemolyticus from environmental samples (Di et al., 2015; Kongrueng et al., 2015; Malcolm et al., 2015). A universal LAMP primer from conserved region of 16S rRNA was designed as a Vibrio species control and result showed the LAMP assay 100 times more sensitive than PCR assay with 100% specificity (Xu et al., 2012).

In addition, a multiplex LAMP (mLAMP) assay is developed for simultaneous detection of two or more Vibrio species by amplifying their DNA in a single tube. Two or more sets of each of the four LAMP primers with total eight or more primers are used in the same reaction mixture (Biswas et al., 2014). A study on a multiplex LAMP was done for the detection of V. harveyi, V. anguillarum and V. alginolyticus from Japanese flounder, shark, seabass and shrimp (Yu et al., 2013). Three sets of four species-specific primers were designed and performed in a single reaction. This assay showed 102 to 103 times more sensitive than the traditional PCR assay. However, in the detection of mLAMP products, the agarose gel electrophoreis was used followed with sequencing or further confirmation of species among these three Vibrios. This detection methods are tedious, time consuming, expensive and requires electrophoresis equipments.

Even though LAMP assay offers a rapid, high sensitivity and specificity and user friendly, but it has a complicated primer design especially for new users. As we know, LAMP assay requires more than one set of primers that target six or eight regions within a target DNA (Notomi et al., 2000). Sometimes, the termination step is required to stop the LAMP reaction by heating at 80oC for two to ten minutes (Biswas et al., 2014). Instead of the LAMP assay, the simplest reaction HDA assay can be used since it requires one set of primers and requires reaction buffer and enzyme mix similar to the PCR assay (Vincent et al., 2004). Moreover, this assay can be performed at 60 to 65oC for less than one hour. However in aquaculture field, there is no publication found regarding the detection of Vibrio species using HDA assay.

Lateral Flow Dipstick

Nowadays, many publications in aquaculture field focused on the detection of Vibrio species by LAMP assay combined with lateral flow dipstick (LFD). Lateral flow dipstick is used as an alternative detection method to the agarose gel electrophoresis, turbidity, fluorescence and restriction enzyme digestion. LFD detection method is a rapid, user-friendly, and easy to perform, highly sensitive and specific and stable at room temperature (Posthuma-Trumpie et al., 2009). Also, it is able to detect multiple pathogenic bacteria simultaneously in one strip. Thus, a multiplex LAMP can be developed and detected via lateral flow dipstick. LFD is known as oligochromatography lateral flow or immunochromatographic test (Brandonisio et al., 2002). It is based on the chromatography technique where the reagents were immobilized on the nitrocellulose strip and reactivated using sample/amplification product for the detection of amplicon.

LAMP assay combined with LFD was developed for the detection of V. alginolyticus targeting rpoX gene (Plaon et al., 2015). The biotin-labeled LAMP product was amplified at 60oC for one hour and hybridized with a fluorescein isothiocyanate (FITC)-labeled probe and result was visualized within five minutes. Result showed that the LAMP-LFD was ten times less sensitive in detection of V. alginolyticus with 100% sensitivity and specificity (Plaon et al., 2015). In 2010, Prompamorn was developed the LAMP-LFD for the detection of V. parahaemolyticus from shrimp samples. The LAMP amplification was performed at 65oC for 90 mins using primers labeled with biotin. The biotinylated LAMP amplicons were then hybridized with a FITC-labeled probe and detected via LFD for five mins. Result showed the detection limit of the LAMP-LFD was 1.8 X 103 CFU g-1 which is ten times more sensitive than PCR assay.

Surasilp (2011) was developed LAMP combined with LFD for the detection of V. vulnificus targeting RNA polymerase subunit sigma factor S (rpoS) gene. The LAMP-LFD was able to detect 1.5 X 103 CFU ml-1 of V. vulnificus from pure culture and also has 100% sensitivity and specificity. Other study showed the LAMP-LFD is successfully developed for the detection of V. harveyi from black tiger shrimp, green mussel and bloody clam (Thongkao et al., 2013). The amplification was performed for 60 mins to produce biotinylated-LAMP products and hybridize with FITC-labeled DNA probe and detected via LFD for five to ten mins. Result showed that the LAMP-LFD is ten times more sensitive than PCR assay in the detection of V. harveyi from shrimp samples.

The combination of LAMP assay and lateral flow dipstick for the detection of vibriosis offers several advantages such as rapid (30 min to one hour), highly sensitive and specific, equipment free and deliverable to end user. Thus, a multiplex LAMP combine with LFD can be a potential diagnostic test for simultaneously detection of Vibrio species from fish, mollusks and other aquatic animals.

Conclusion

In conclusion, the isothermal amplification assay especially LAMP is capable for the detection of Vibrio species. The simplicity of lateral flow dipstick and LAMP assay offer great potentials for the development of nucleic acid diagnostic devices that could be used to detect vibriosis at point-of-care or in the field.

Acknowledgement

This work (LAMP development) was supported by the grants provided by Ministry of Higher Institution via Higher Institution Centre of Excellence (HICoE) under Vote No: 6369100.

References

Adams, A. and Thompson, K.D. (2011) Development of diagnostics for aquaculture: challenges and opportunities. Aquaculture Research. Vol. 42 Pages 93-102.

Alaboudi, A.R., Ababneh, M., Osaili, T.M. and Shloul, K.A. (2016) Detection, Identification, and Prevalence of Pathogenic Vibrio parahaemolyticus in Fish and Coastal Environment in Jordan. Journal of Food Science.Vol. 81 No (1) Pages 130-134.

Alam, M.J., Miyoshi, S. and Shinoda, S. (2003) Studies on pathogenic Vibrio parahaemolyticus during a warm weather season in the Seto Inland Sea, Japan. Environmental Microbiology.Vol. 5 Pages 706-710.

Amin, R.A. and Salem, A.M (2012) Specific Detection of Pathogenic Vibrio species inShellfish by Using Multiplex Polymerase Chain Reaction. Global Veterinaria. Vol. 8 No (5) Pages 525-531.

Biswas, G. & Sakai, M. (2014) Loop-mediated Isothermal Amplification (LAMP) Assays for Detection and Identification of aquaculture pathogens: Current State and Perspectives. Applied Microbiology and Biotechnology. Vol 98 Page 2881.

Bramhachari, P.V. and Dubey, S.K. (2006) Rapid and specific detection of luminous and non-luminous Vibrio harveyi isolates by PCR amplification. Current Science. Vol. 90 Pages 1105-1108.

Brandonisio, O., Fumarola, L., Maggi, P., Cavaliere, R., Spinelli, R., Pastore, G. (2002) Evaluation of a Rapid Immunochromatographic Test for Serodiagnosis of Visceral Leishmaniasis. European Journal of Clinical Microbiology & Infectious Diseases. Vol 21 Pages 461–464.

Buller, N.B. (2014) Bacteria and Fungi from Fish and other Aquatic Animals, 2nd edition: A Practical Identification Manual. CABI Publishing, UK.Pages 214-217.

Cai, S.H., Lu, Y.S., Wu, Z.H., Jian, J.C., Wang, B. and Huang, Y.C. (2010) Loop-mediated isothermal amplification method for rapid detection of Vibrio alginolyticus, the causative agent of vibriosis in mariculture fish. The Society for Applied Microbiology, Letters in Applied Microbiology.Vol. 50 Pages 480–485.

Canajero, M.J.U. and Hedreyda, C.T. (2003) Isolation of partial toxR gene of Vibrio harveyi and design of toxR-targeted PCR primers for species detection. Journal of Applied Microbiology. Vol. 95 Pages 602–611.

Centers for Disease Control and Prevention (CDC) (2013) Increase in Vibrio parahaemolyticus illnesses associated with consumption of shellfish from several Atlantic coast harvest areas, United States, 2013. Accessed on 11 Mei 2016 at http://www.cdc.gov/vibrio/investigations/

Chatterjee, S. and Haldar, S. (2012) Vibrio Related Diseases in Aquaculture and Development of Rapid and Accurate Identification Methods. Journal of Marine Science: Research & Development. Vol.1 Pages 1-17.

Chen, D., Hanna, P.J., Altmann, K., Smith, A., Moon, P. and Hammond, L.S. (1992) Development of Monoclonal Antibodies That Identify Vibrio Species Commonly Isolated from Infections of Humans, Fish, and Shellfish. Applied and Environmental Microbiology. Vol. 58 No (11) Pages 3694-3700.

Chiou, C.S., Hsu, S.Y., Chiu, S.J., Wang, T.K. and Chao, C.S. (2000) Vibrio parahaemolyticus serovar O3:K6 as cause of unusually high incidence of food-borne disease outbreaks in Taiwan from 1996 to 1999. Journal of Clinical Microbiology.Vol. 38 Pages 4621-4625.

Chow, W. H. A., McCloskey, C., Tong, Y., Hu, L.,You, Q., Kelly, C. P., Kong, H., Tang, Y.-W. and Tang, W. (2008). Application of Isothermal Helicase-Dependent Amplification with a Disposable Detection Device in a Simple Sensitive Stool Test for Toxigenic Clostridium difficile. The Journal of Molecular Diagnostics.Vol. 10 No (5) Pages 452-458.

Compton, J. (1991). Nucleic acid sequence-based amplification. Nature.Vol.350 No (6313) Pages 91-92.

Deepanjali, A., Kumar, H.S., Karunasagar, I. and Karunasagar, I. (2005) Seasonal variation in abundance of total and pathogenic Vibrio parahaemolyticus bacteria in oysters along the southwest coastal of India. Applied and Environmental Microbiology. Vol. 71 Pages 3575-3580.

Di, H., Ye, L., Neogi, S.B., Meng, H., Yan, H., Yamasaki, S. and Shi, L. (2015) Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay Combined with Enrichment Culture for Rapid Detection of Very Low Numbers of Vibrio parahaemolyticus in Seafood Samples.Biological and Pharmaceutical Bulletin.Vol. 38 Pages 82–87.

Edwards, P., Little, D.C. and Demaine, H., (2002) Rural aquaculture. CABI publisihing, UK. Page 358.

Fang, X., Liu, Y., Kong, J. and Jiang, X. (2010) Loop-mediated isothermal amplification integrated on microfluidic chips for point-of-care quantitative detection of pathogens. Analytical Chemistry.Vol.82 No (7) Pages 3002-3006.

Fire, A. and Xu, S.Q. (1995) Rolling replication of short DNA circles. Proceedings of the National Academy of Sciences.Vol.92 No (10) Pages 4641-4645.

Food and Agriculture Organization of the United Nations (FAO) (2013) FAO Statistical Yearbook 2013 World Food and Agriculture. Pages 146-149.

Foodborne Diseases Active Surveillance Network (FoodNet): FoodNet Surveillance Report for 2014 (Final Report). Atlanta, Georgia: U.S. Department of Health and Human Services, CDC. 2016. http://www.cdc.gov/foodnet/reports/annual-reports-2014.html. Accessed April 21, 2016.

Gargouti, A.S., Ab-Rashid, M. N.K., Ghazali, M.F., Mitsuaki, N., Haresh, K.K. and Radu, S. (2015) Detection of tdh and trh Toxic Genes in Vibrio Alginolyticus Strain from Mantis Shrimp (Oratosquilla Oratoria). Journal of Nutrition & Food Sciences.Vol.5 No (5) Pages 1-4.

Gauthier, T. (2015) Bacterial zoonoses of fishes: A review and appraisal of evidence for linkages between fish and human infections. The Veterinary Journal. Vol. 203 Pages 27–35.

Gill, P. and Ghaemi, A. (2008) Nucleic Acid Isothermal Amplification Technologies – AReview. Nucleosides, Nucleotides and Nucleic Acids.Vol.27 No (3) Pages 224 – 243.

Gomathi, R.S., Vinothkumar, R. and Arunagiri, K. (2013) Isolation and identification Vibrios from marine seafood samples.International Journal of Current Microbiology and Applied Sciences. Vol.2 No (2) Pages36-43.

Haldar, S., Chatterjee, S., Sugimoto, N., Das, S., Chowdhury, N., Hinenoya A., Asakura M., Yamasaki S. (2011) Identification of Vibrio campbelii isolated from diseased farm-shrimps from South India and establishment of its pathogenic potential in an Artemia model. Microbiology.Vol. 157 Pages 79-188.

He, L. and Xu, H.S. (2011) Development of a multiplex loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M.avium and M.intracellulare in sputum samples. Journal of Clinical Microbiology. Vol. 41 No (6) Pages 2616-2622.

Hoorfar, J., Cook, N., Malorny, B., Wegner, M., Medici, D.D., Abdulmawjood, A. and Fach, P. (2003) Making internal amplification control mandatory for diagnostic PCR. Journal of Clinical MicrobiologyVol.41 No (12) Pages 5835.

Izumiya, H., Matsumoto, K., Yahiro, S., Lee, J., Morita, M., Yamamoto, S., Arakawa, E. and Ohnishi, M. (2011) Multiplex PCR assay for identification of three major pathogenic Vibrio spp., Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus. Molecular and Cellular Probes. Vol.25 Pages 174-176.

Jones, J.L., Hara-Kudo, Y., Krantz, J.A., Benner Jr, R.A., Smith, A.B., Dambaugh, T.R., Bowers, J.C. and DePaola, A. (2012) Comparison of molecular detection methods foVibrio pahaemolyticus and Vibrio vulnificus. Food MicrobiologyVol.30 Pages 105-111.

Kim, M.S. and Jeong, H.D. (2001) Development of 16S rRNA tageted PCR methods for the detection and differentiation of Vibrio vulnificus in marine environments. AquacultureVol.193 Pages 199-211.

Kim, Y.B., Okuda, J., Matsumoto,C., Takahashi, N., Hashimoto, S. and Nishibuchi, M. (1999) Identification of Vibrio parahaemolyticus strains at the species level by PCR targeted to the toxR gene. Journal of Clinical Microbiology. Vol. 37 No (4) Pages 1173-1177.

Kongrueng, J., Tansila, N., Mitraparp-arthorn, P., Nishibuchi, M., Vora, G.J. and Vuddhakul, V. (2015) LAMP assay to detect Vibrio parahaemolyitcus causing acute hepatopancreatic necrosis disease in shrimp. Aquaculture International.Vol. 23 Pages 1179-1188.

Lequin, R.M. (2005) Enzyme Immunoassay (EIA)/Enzyme-linked Immunosorbent Assay (ELISA). Clinical Chemistry.Vol. 51 No (12) Pages 2415-2418.

Li, R., Chious, J., Chan, E.C. and Chen, S. (2016) A novel PCR-based approach for accurate identification of Vibrio parahaemolyticus. Frontiers in MicrobiologyVol.44 No (7) Pages 1-5.

Mabey, D., Peeling, R.W., Ustianowski, A., Perkins, M.D. and Free, R. (2004) Diagnostics for the developing world. Tropical Infectious DiseasesVol.2 Pages 1-10.

Malcolm, T.T.H., Cheah, Y.K., Radzi, C.W.J.W.M., Kasim, F.A., Kantilal, H.K., John, T.Y.H., Martinez-Urtaza, J., Nakaguchi, Y., Nishibuchi, M. and Son, R. (2015) Detection and quantification of pathogenic Vibrio parahaemolyticus in shellfish by using multiplex PCR and loop-medated isothermal amplification assay. Food Control.Vol. 47 Pages 664-671.

Mishra, S.S. (1998) Use of dot immunoassay for rapid detection of pathogenic bacteria Vibrio alginolticus and Aeromonas hydrophila from shrimps and fishes. Indian Journal of Geo-Marine Sciences.Vol.27 No (2) Pages 222-226.

Mohammed, A.M. and Jerjees, S.G. (2015) Detection of tdh and trh genes from Vibrio parahaemolyticus isolated from gastroenteritis cases and shrimp samples. International Journal of Advanced Research. Vol. 3 No (2) Pages 288-294.

Mori, Y. and Notomi, T. (2009). Loop-mediated isothermal amplification (LAMP): a rapid, accurate, and cost-effective diagnostic method for infectious diseases. Journal of Infection and Chemotherapy.Vol.15 No (2) Pages 62-69.

Mugasa, C. M., Laurent, T., Schoone, G. J., Kager, P. A., Lubega, G. W., and Schallig,H.D.F.H. (2009). Nucleic Acid Sequence-Based Amplification with Oligochromatography for Detection of Trypanosoma brucei in Clinical Samples. Journal of Clinical Microbiology.Vol.47 No (3) Pages 630-635.

Mustapha, S., Mustapha, E.M. and Nozha, C. (2013) Vibrio alginolyticus: An emerging pathogen of foodborne diseases. International Journal of Science and Technology.Vol.2 No (4) Pages 302-309.

Notomi, T., Okayama, H., Masubuchi, H., Yonekawa, T., Watanabe, K., Amino, N. and Hase, T. (2000). Loop-mediated isothermal amplification of DNA. Nucleic Acids Research.Vol.28 No (12) Pages E63.

Plaon, S., Longyant, S., Sithigorngul, P. & Chaivisuthangkura, P. (2015) Rapid and Sensitive Detection of Vibrio alginolyticus by Loop Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick Targeted to the rpoX Gene. Journal of Aquatic Animal Health. Vol 27 No (3) Pages 156-163.

Posthuma-Trumpie, G.A., Korf, J. & van Amerongen, A. (2009) Lateral flow (immuno) assay: Its Strengths, Weaknesses, Opportunities and Threats. Analytical and Bioanalytical Chemistry. Vol. 393 No (2) Pages 569-582.

Prompamorn, P., Sithigorngul, P., Rukpratanporn, S., Longant, S., Sridulyakul, P. and Chaivisuthangkura, P. (2011) The development of loop-mediated isothermal amplification combined with lateral flow dipstick for detection of Vibrio parahaemolyticus.Letters in Applied Microbiology. Vol. 52 Pages 344-351.

Romalde, J.L., Magarinos, B., Fouz, b., Bandin, I., Nunez, S. and Toranzo, A.E. (1995) Evaluation of BIONOR Mono-kits for rapid detection of bacterial fish pathogens. Diseases of Aquatic OrganismsVol.21 Pages 25-34.

Scallan, E., Hoekstra, R.M., Angulo, F.J., Tauxe R.V., Widdowson M.A., Roy S.L., Jones J.L., Griffin P.M. (2011) Foodborne illness acquired in the United States- major pathogens. Emerging Infectious Disease. Vol.17 No (1) Pages 7-15.

Surasilpa, T., Siwaporn, L., Rukpratanpornb, S., Sridulyakula, P., Sithigorngula, P., Chaivisuthangkura, P. (2011) Rapid and sensitive detection of Vibrio vulnificus by loop-mediated isothermal amplification combined with lateral flow dipstick targeted to rpoS gene. Molecular and Cellular Probes Vol. 25 No (4) Pages 158–163.

Thongkao, K., Siwaporn L., Silprasit K., Sithigorngul, P. & Chaivisuthangkura, P. (2013) Rapid and Sensitive Detection of Vibrio harveyi by Loop-mediated Isothermal Amplification Combined with Lateral Flow Dipstick Targeted to vhhP2 Gene. Aquaculture Research. Pages 1–10

Vincent, M., Xu, Y. and Kong, H. (2004). Helicase-dependent isothermal DNA amplification. EMBO reportsVol.5 No (8) Pages 795-800.

Wain, J., and Hosoglu, S. (2008). Review Article: The laboratory diagnosis of enteric fever.Journal of Infection in Developing Countries.Vol.2 No (6) Pages 421-425.

Walker, G. T., Little, M. C., Nadeau, J. G. and Shank, D. D. (1992). Isothermal in vitro amplification of DNA by a restriction enzyme/ DNA polymerase system. Proceedings of the National Academy of Sciences.Vol.89 No (1) Pages 392-396.

Wang, X., Yuan, Y., Wang, H., Zhou, Q., Zhu, J., Chang, Y., Cui, Y. and Qiu, X. (2009) Phylogenetic analysis of four Vibrio strains of pathogenic bacteria based on hemolysin genes and 16S rRNA genes. Book of Abstract; 3rd International Conference on Bioinformatics and Biomedical Engineering. Pages 1-4.

Wei, S., Zhao, H., Xian, Y., Hussain, M.A. and Wu, X. (2014) Multiplex PCR assays for the detecton of Vibrio alginolyticus, Vibrio parahaemolyticus, Vibrio vulnificus and Vibrio cholerae with an internal amplification control.Diagnostic Microbiology and Infectious Disease.Vol. 79 Pages 115-118.

Xie Z.Y., Hu C.Q., Chen, C., Zhang, L.P. and Ren C.H. (2005) Investigation of seven Vibrio virulence genes among Vibrio alginolyticus and Vibrio Parahaemolyticus strains from the coastal mariculture systems in Guangdong, China. Letters in Applied Microbiology.Vol. 41Pages 202-207.

Xu, H., He, L., Lv, S., Gong, Q. and Li, S. (2012) Establishment of universal loop-mediated isothermal amplification method (LAMP) for rapid detection of pathogenic Vibrio spp. In aquatic organisms. African Journal of Microbiology Research. Vol.6 No (14) Pages 3447-3454.

Xu, Y., Cui, L., Liu, Z., Li, D., Li, S. and Zhao, M. (2014) Simultneous detection of five pathogenic Vibrio species in seafood by a multiplex polymerase chain reaction coupled with high performane liquid chromatography assay. Food ControlVol.53 Pages 109-116.

Yong, L., Guanpin, Y., Hualei, W., Jixiang, C., Xianming, S., Guiwei, Z., Qiwei, W. and Xiuqin, S. (2006) Design of Vibrio 16S rRNA gene specific primers and their application in the analysis of seawater Vibrio community. Journal of Ocean University of China.Vol.5 No (2) Pages 157-164.

Yu, L. P., Hu, Y. H., Zhang, X. H, Sun, B. G. (2013) Development of a Triplex Loop-Mediated Isothermal Amplification Method for Rapid On-Site Detection of Three Vibrio Species Associated With Fish Diseases. Aquaculture Vol. 414–415 Pages 267–
273.